Код ошибки кондиционера lg ch38

LG Error code CH38 in LG AC

Troubleshooting
HRV, Multi V, Split Air Conditioners
10/28/2022

Facebook Share

Twitter Share

Pinterest

EMAIL

  • Print
  • Email
  • Copy Link

Error code: CH38 in LG AC


 


Symptom


 


 


  •  

     

    CH38


 




 


Possible Cause


  •  


    The CH38 error code will appear when the refrigerant (gas) level of the appliance is low, to protect the appliance.

     

     

 

Solution or Settings


1.

 

 

 

Did the CH38 error code appear after installing/re-installing the appliance?


  •  

    CH38 error can occur when the refrigerant level of the appliance is low. The technician must check if there is sufficient amount of refrigerants.


 

2.

 

 

 

Did the CH38 error code appear after using the appliance for a period of time?

 

 


  •  

    Electrical problems such as electrical instability can cause temporary error. Unplug the power

     


    cord or shut off the circuit breaker and turn the power on after 5 minutes. If the error continues after   asking the above measure, request for a

    qualified technician to inspect the appliance.

Summary


  •  



    The CH38 error code will appear when the refrigerant (gas) level is low, to protect the appliance.

 

Facebook Share

Twitter Share

Pinterest

EMAIL

  • Print
  • Email
  • Copy Link

*Required question

Thank you for your feedback!

Какая ошибка у вашего кондиционера?

Код ошибки: CH-01

Датчик температуры воздуха в помещении неисправен

Короткое замыкание в цепи датчика, обрыв цепи датчика. Попадание влаги в датчик, Неисправен контакт в разъеме, Вышла из строя плата управления

Код ошибки: CH-02

Датчик температуры хладагента, который находится при входе в теплообменник, неисправен

Короткое замыкание в цепи датчика, обрыв цепи датчика. Попадание влаги в датчик, Неисправен контакт в разъёме, Вышла из строя плата управления

Ремонт внешнего блока сплит-системы

Код ошибки: CH-03

Нет соединение с проводным пультом

Плохой контакт на плату управления в пульте управления, окисление контактов, перестал функционировать пульт управления, не работает плата управления ( то есть компоненты, отвечающие за соединение с пультом управления)

Проверьте провода пульта управления на наличие повреждений. — Проверьте состояние контактов в разъёме подключения соединительного провода на плате и на ПУ — Необходимо прозвонить соединительный провод — Убедиться что пульт управления исправен и работоспособен — Убедиться что плата управления цела.

Код ошибки: CH-04

Не работает дренажный насос

Дренажный шланг может быть забит, двигатель насоса неисправен, цепь поплавкового датчика разомкнута

Проверить двигатель дренажного насоса на исправность, оценить состояние дренажного шланга, проверить правильность установки дренажного насоса

Решение не помогло или нужно больше информации?
Проконсультируйтесь со специалистом или вызовите мастера!

Код ошибки: CH-05

В связи между внутренним и наружным блоком присутствует ошибка

Отсутствует питание на внутреннем или наружном блоке, ошибка подключения кабеля питания. Мотор вентилятора вышел из строя. Ошибка связи из-за внешних помех, если рядом пролегает электрический кабель.

Прежде всего проверить подключения кабеля, проверить наличие напряжения на плате управления блоков. Проверить исправность двигателя вентилятора.

Код ошибки: CH-06

Датчик, который расположен на выходе из теплообменника внутреннего блока, неисправен

Короткое замыкание в цепи датчика, обрыв цепи датчика. Попадание влаги в датчик, Неисправен контакт в разъёме, Вышла из строя плата управления

Код ошибки: CH-07

Ошибка EEPROM (ПЗУ)

Неисправен контакт ПЗУ на плате управления

Необходимо проверить контакт и правильность установки чипа ПЗУ

Код ошибки: CH-10

Неисправность БДПТ электродвигателя вентилятора внутреннего блока

Остановка вентилятора из-за внешнего воздействия — Плохой контакт в разъёме на плате управления — Неисправность двигателя — Плата неисправна

Устраните внешние воздействия — Проверьте контакт разъёма — Проверьте двигатель вентилятора — Проверьте плату управления

Код ошибки: CH-12

Датчик, который находится в центральной части теплообменника внутреннего блока, неисправен

Короткое замыкание в цепи датчика, обрыв цепи датчика. Попадание влаги в датчик, Неисправен контакт в разъёме, Вышла из строя плата управления

Обслуживание вентиляции

Код ошибки: СН21

Повышенный потребляемый ток компрессора с инверторным приводом

— Утечка хладагента — Компрессор заклинен — Плата инвертора неисправна

— Проверьте контур на возможность утечки хладагента — Проверить на неисправность силовые элементы платы управления компрессором — Проверить цепь электродвигателя компрессора на предмет обрывов и короткого замыкания

Обслуживание вентиляции

Код ошибки: СН22

Перегрузка. Повышенный потребляемый ток наружного блока

Загрязненный теплообменник наружного блока, низкая циркуляция охлаждающего воздуха в месте установки наружного блока (есть помехи для теплообмена, вентилятор загражден). Также причиной может являться низкое напряжение у источника питания

— Проверить напряжение источника питания — Проверить циркуляцию охлаждающего воздуха в месте, где установлен наружный блок (проверить, чтобы блоку ничего не мешало проводить теплообмен). — Прочистить фильтр внутреннего блока и теплообменник наружного блока

Обслуживание вентиляции

Код ошибки: СН23

Слишком низкое или высокое напряжение сети

Плата управления компрессором неисправна, низкое напряжение у источника питания, Плохо закреплен провод

Проверить качество подключения к источнику питания. Проверить подключения проводов реактора. Проверить датчик напряжение на исправность

Код ошибки: СН26

При запуске компрессора возникает неисправность

Компрессор вышел из строя, плата управления компрессором неисправна, На разъеме компрессора присутствует дефект провода

— Проверить провода компрессора на наличие дефектов — Проверить плату управления компрессора на работоспособность

Обслуживание вентиляции

Код ошибки: СН27

Перегрузка тока в цепи конвектора (преобразователя тока AC –DC)

— Работа кондиционера на перегрузках, недостаточная циркуляция воздуха в местах крепления внешнего блока кондиционера — Повреждение элементов выпрямителя PSC в плате управления — Неверные характеристики реактора

— Проверить циркуляцию воздуха в районе наружного блока — Проверить характеристики реактора

Код ошибки: СН32

Температура выше нормы нагнетания компрессора

-Датчик, который отвечает за измерение температуры нагнетания, неисправен — Утечка или недостаточное количество хладагента — Плохие контакты разъемов

-Проверить в местах крепления наружного блока хорошую циркуляцию воздуха — Поверить количество хладагента в системе, исключить утечку — Проверить датчик температуры нагнетания на исправность, проверить подключения разъемов к плате управления

Код ошибки: СН34

Высокое давление хладагента в системе

Циркуляция воздуха через теплообменник затруднена (фильтр внутреннего блока загрязнен, в случае работы в режиме охлаждения или обмерзший теплообменник наружного блока в случае работы в режиме обогрева) — Количество хладагента в системе меньше допустимой нормы — Проблемы с платой управления — Разъемы неисправны

Проверить в местах крепления наружного блока хорошую циркуляцию воздуха — Поверить количество хладагента в системе, исключить утечку — Проверить датчик температуры нагнетания на исправность — Проверить подключения разъемов к плату управления — Прочистить фильтры при условии их загрязнения

Код ошибки: CH35

Низкое давление хладагента в системе

— Циркуляция воздуха через теплообменник затруднена (фильтр внутреннего блока загрязнен, в случае работы в режиме охлаждения или обмерзший теплообменник наружного блока в случае работы в режиме обогрева) — Количество хладагента в системе меньше допустимой нормы — Проблемы с платой управления — Разъемы неисправны

— Проверить в местах крепления наружного блока хорошую циркуляцию воздуха — Поверить количество хладагента в системе, исключить утечку — Проверить датчик температуры нагнетания на исправность — Проверить подключения разъемов к плату управления — Прочистить фильтры при условии их загрязнения

Код ошибки: СН41

Датчик температуры нагнетания инверторного компрессора неисправен

— В цепи датчика случился обрыв или короткое замыкание — Отходит контакт в разъеме на блоке управления — Неисправность платы управления

— Проверить разъемы датчиков — Проверить сопротивление датчика: — СН41 — 200 кОм при 25°C (при отключенном датчике) — СН44 -10 кОм при 25°C (при отключенном от платы датчике) — СН45/48 — 5 кОм при 25°C (при отключенном от платы датчике) — СН46 — 5 кОм при 25°C (при отключенном от платы датчике)

Код ошибки: СН44

Неисправность датчика температуры уличного воздуха

— В цепи датчика случился обрыв или короткое замыкание — Отходит контакт в разъеме на блоке управления — Неисправность платы управления

— Проверить разъемы датчиков — Проверить сопротивление датчика: — СН41 — 200 кОм при 25°C (при отключенном датчике) — СН44 -10 кОм при 25°C (при отключенном от платы датчике) — СН45/48 — 5 кОм при 25°C (при отключенном от платы датчике) — СН46 — 5 кОм при 25°C (при отключенном от платы датчике)

Код ошибки: СН45/48

Неисправность или ошибка датчика температуры трубки теплообменника наружного блока кондиционера

— В цепи датчика случился обрыв или короткое замыкание — Отходит контакт в разъеме на блоке управления — Неисправность платы управления

— Проверить разъемы датчиков — Проверить сопротивление датчика: — СН41 — 200 кОм при 25°C (при отключенном датчике) — СН44 -10 кОм при 25°C (при отключенном от платы датчике) — СН45/48 — 5 кОм при 25°C (при отключенном от платы датчике) — СН46 — 5 кОм при 25°C (при отключенном от платы датчике)

Код ошибки: СН46

Ошибка датчика температуры на линии всасывания компрессора

— В цепи датчика случился обрыв или короткое замыкание — Отходит контакт в разъеме на блоке управления — Неисправность платы управления

— Проверить разъемы датчиков — Проверить сопротивление датчика: — СН41 — 200 кОм при 25°C (при отключенном датчике) — СН44 -10 кОм при 25°C (при отключенном от платы датчике) — СН45/48 — 5 кОм при 25°C (при отключенном от платы датчике) — СН46 — 5 кОм при 25°C (при отключенном от платы датчике)

Код ошибки: СН61

Температура конденсации превышает норму

Работа наружного блока в недостаточной циркуляции воздуха, что способствует перегрузкам. Теплообменник загрязнен. Неисправность датчика температуры конденсации

Проверить и обеспечить нормальную циркуляцию воздуха в местах крепления наружного блока кондиционера. Проверить не перезаправлена ли система фреоном. Проверить корректность установки термодатчика

Код ошибки: СН62

Перегрев радиатора силового транзистора на плате управления компрессором

— Вентилятор наружного блока кондиционера заклинил — Неправильное место установки наружного блока — Неисправность контура — Неисправность датчика температуры

— Проверьте состояние вентилятора наружного блока — Проверьте место установки наружного блока — Проверьте разъём соединения датчика — Проверьте контур датчика на плате управления компрессором

Код ошибки: СН67

Неисправность электродвигателя вентилятора наружного блока

— Вентилятор заклинил по механическим причинам — Электродвигатель вентилятора вышел из строя

— Проверить есть ли помеха работе вентилятора внешними предметами — Оценить работоспособность двигателя вентилятора — Проверьте плату управления (элементы контура управления вентилятором)

Код ошибки: СН72

Неисправность при переключении 4-х ходового клапана

— Разомкнут разъём подключения на плате — Привод 4-х ходового разомкнут, либо замкнут — Проблема платы управления

— Проверьте функциональность подключения на плате управления — Проверьте сопротивление катушки привода — Проверьте напряжение на плате управления

00 Text the 1, 2 or 3 digit fault code number only. I.e. If you see fault code CH07 on your indoor unit or R/Controller, only type 7 or 07 in your text message. 01 Indoor unit return air sensor fault. Disconnect sensor from PCB and measure resistance. 8 kOhm at 30C and 13 kOhm at 20C if not replace sensor 1 Indoor unit return air sensor fault. Disconnect sensor from PCB and measure resistance. 8 kOhm at 30C and 13 kOhm at 20C if not replace sensor 02 Indoor Pipe Sensor or Outdoor Sensor Assy fault, Open or Short. Disconnect from PCB and measure resistance. Air sensor = 10 kOhm at 25C, Pipe sensor = 5 kOhm at 25C. If not replace sensor. 2 Indoor Pipe Sensor or Outdoor Sensor Assy fault, Open or Short. Disconnect from PCB and measure resistance. Air sensor = 10 kOhm at 25C, Pipe sensor = 5 kOhm at 25C. If not replace sensor. 03 Remote controller comms error. Check wired correctly, if so check dipswitch in RC. Set to Sg for 1 unit, or Gr for group then reset power 3 Remote controller comms error. Check wired correctly, if so check dipswitch in RC. Set to Sg for 1 unit, or Gr for group then reset power 04 RAC Product = Heat Sink Sensor Error, Open/Short Cct or over 95C. Commercial Product = Condensate pump float switch risen. Check drain pan is empty, check pump is working OK. If no pump check blue jumper plug is inserted in socket CN Float. 4 RAC Product = Heat Sink Sensor Error, Open/Short Cct or over 95C. Commercial Product = Condensate pump float switch risen. Check drain pan is empty, check pump is working OK. If no pump check blue jumper plug is inserted in socket CN Float. 05 Comms Error, check your wiring, remove external pumps. Split/Multi — check volts from terminal N to 3 = 0 — 65 Vdc, Multi V — 4 Vdc terminals 3 and 4 5 Comms Error, check your wiring, remove external pumps. Split/Multi — check volts from terminal N to 3 = 0 — 65 Vdc, Multi V — 4 Vdc terminals 3 and 4 06 Indoor unit coil sensor fault. Disconnect from PCB measure resistance. 10 kOhm at 10C and 4 kOhm at 30C. if not replace sensor. Split = text 21 6 Indoor unit coil sensor fault. Disconnect from PCB measure resistance. 10 kOhm at 10C and 4 kOhm at 30C. if not replace sensor. Split = text 21 07 Multi Splits and Multi V = indoor unit is set to run in a different mode from the master indoor unit. Set ALL indoor units to cooling or ALL to heating to clear. Splits = Compressor Over Current (CT2), also see Code 06. 7 Multi Splits and Multi V = indoor unit is set to run in a different mode from the master indoor unit. Set ALL indoor units to cooling or ALL to heating to clear. Splits = Compressor Over Current (CT2), also see Code 06. RAC Indoor unit BLDC Fan problem. This is caused by the Indoor fan being locked. Check fan motor is plugged in correctly, Electrically & Mechanically sound. 08 Check the fan motor turns freely, check the AC Voltage supplied to the fan motor, this will vary from 120 V ac at low speed to 170V AC at high speed. If no Voltage is present the the PCB is faulty, if Voltage is present the fan motor will be Faulty. RAC Indoor unit BLDC Fan problem. This is caused by the Indoor fan being locked. Check fan motor is plugged in correctly, Electrically & Mechanically sound. 8 Check the fan motor turns freely, check the AC Voltage supplied to the fan motor, this will vary from 120 V ac at low speed to 170V AC at high speed. If no Voltage is present the the PCB is faulty, if Voltage is present the fan motor will be Faulty. 09 Split = Outdoor unit fan problem. Check Outdoor fan motor is plugged in, Electrically & Mechanically sound, if not replace motor, otherwise replace PCB. Multi V = Indoor unit EEPROM error — Replace the indoor unit PCB, and then make sure to do Auto addressing and input the address of central control. 9 Split = Outdoor unit fan problem. Check Outdoor fan motor is plugged in, Electrically & Mechanically sound, if not replace motor, otherwise replace PCB. Multi V = Indoor unit EEPROM error — Replace the indoor unit PCB, and then make sure to do Auto addressing and input the address of central control. 10 RAC Product: Compressor discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20°C, 168 kOhm at 30C. Multi Fdx & Multi V text 8 11 Multi V indoor unit not connected to an outdoor unit. Check comms wiring is correct, and check initialisation has been carried out correctly 12 RAC Product = EEPROM Sum Check Error, text 60 for help. 13 RAC Product = PSC (Reactor) Error, text 27 for help. 14 RAC Product = Compressor Phase Current Error 15 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message 16 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message 17 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message 18 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message 19 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message 20 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message 21 Inverter compressor run current high. Check compressor windings all equal 1 to 4 Ohms, Check to earth 50 MOhm minimum, check run current 22 Inverter compressor run current high. Check compressor windings all equal 1 to 4 Ohms . Check to earth 50 MOhm minimum, check run current 23 Inverter dc voltage low. Check dc voltage of capacitors 300 Vdc for 1Ph and 600 Vdc for 3Ph. If OK change outdoor inverter PCB 24 Splits and Multi Splits = High or low pressure trip. Low at 1 bar High at 35 bar check pressures. Multi V = High pressure trip. 25 Check power supply voltage to the outdoor unit is correct (1ph ?220 Vac ±10% or 3ph ?380 Vac ±10%). If OK, check fuses, if fuses are OK replace outdoor main PCB 26 Inverter compressor seized. Check compressor windings all equal resistance 1 to 4 Ohms, check to earth 50 MOhm minimum, check run current and Inverter outputs 27 Inverter current irregularity. Check inverter PCB, check reactor connections and its resistance is less than 1 ohm. 28 Inverter dc voltage too high. Check dc voltage of capacitors 300 Vdc for 1Ph and 600 Vdc for 3Ph. If OK change outdoor inverter PCB 29 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message 30 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message 31 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message 32 Inverter compressor discharge temperature too high. If over 105°C, check refrigerant charge 33 Excessive rise of standard compressor discharge temperature. If over 105°C check refrigerant charge 34 Excessive high pressure rise, over 35 bar at HP sensor. Check pressures, check coils, and filters are clean check for OFN in system pipework 35 Excessive low pressure drop under 1 Bar at LP sensor. Check pressures, and check service valves open 36 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message 37 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message 38 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message 39 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message 40 Inverter ac current abnormal. Check compressor windings all equal resistance 1 to 4 Ohms, check to earth 50 MOhm minimum, check run current and inverter outputs 41 Inverter compressor discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20°C and 168 kOhm at 30°C. 42 Low pressure sensor fault. Check dc voltage between white and black cable on plug. Multi V: 1 Vdc = 4 bar up to 5 Vdc = 32 bar 43 High pressure sensor fault. Check dc voltage between white and black cable on plug. Multi V: 1 Vdc = 8 bar up to 2.5 Vdc = 37 bar 44 Outdoor unit air sensor fault. Disconnect from PCB and measure resistance. 8 kOhm at 30C and 13 kOhm at 20C. If OK replace PCB, if not replace sensor 45 Outdoor unit coil sensor fault. Disconnect from PCB measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace sensor 46 Outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace sensor 47 Compressor discharge sensor fault. Disconnect from PCB measure resistance. 237 kOhm at 20°C and 168 kOhm at 30°C. If OK replace PCB, if not replace sensor 48 Split/Multi Split = Outdoor unit discharge and air sensor both unplugged. Multi V = Outdoor unit coil sensor. Text 45 for diagnostics 49 Check power supply voltage to the outdoor unit is correct (1ph ?220 Vac ±10% or 3ph ?380 Vac ±10%). If OK check fuses, if fuses OK, replace outdoor main PCB 50 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message 51 Unit mismatch. Check model number of units do not exceed maximum. Multi V — also check Sub outdoor unit dipswitch settings 52 Communication error between inverter PCB and main outdoor unit PCB. Check wiring fuses and LEDs . If OK either inverter or main PCB defective 53 Comms error indoor to outdoor unit. Check your wiring . Split and Multi — check voltage from terminal N to 3 = 0 — 65 Vdc, Multi V — 4 Vdc terminals 3 and 4 54 Reverse or open phase. Check all 3 phases are present and correct. If correct voltage appears at all three phases, swap any two to cure the fault 55 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message 56 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message 57 Comms error between outdoor main PCB and inverter PCB. Check wiring fuses and LEDs are lit. If OK either inverter or main PCB defective 58 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message 59 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message 60 Outdoor unit PCB EEPROM failure, try removing EEPROM and refitting if removable (possible contact fault), otherwise replace PCB if the EEPROM is non-removable. 61 Condenser coil over 65°C. Check coil and filters are clean and free from debris, and airflow is OK. Check system pressures for non-condesables 62 Inverter over 85°C. Check air flow across heat sink, check inverter tight to heatsink use thermal paste. Multi V — check inverter cooling fan 63 Multi F(DX) — «Cond. Pipe Sensor Temp. Low» (opposite to Error Code 61). Check Temperature/Resistance reading and replace sensor if found to be faulty. If sensor okay, check for cause of low temperature and rectify. 64 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message 65 Outdoor unit inverter fin temperature sensor fault. Disconnect from PCB measure resistance. 8 kOhm at 30°C and 13 kOhm at 20°C 67 Outdoor Fan Motor siezed, or rotation sensing circuit failure. Check motor for mechanical and/or electrical failure, if okay replace pcb. 100 Excessive discharge temperature rise 105°C Sub condenser 1 standard compressor. Check refrigerant 101 Excessive discharge temperature rise 105°C Sub condenser 1 standard compressor. Check refrigerant 102 Excessive discharge temperature rise 105°C Sub condenser 2 standard compressor. Check refrigerant 103 Excessive discharge temperature rise 105°C Sub condenser 2 standard compressor. Check refrigerant 104 Communication error between Main and Sub outdoor units. Check comms wiring and power to all outdoor units 105 Communication error between outdoor main PCB and fan PCB. Check plug connections and LEDs. If OK, replace either main or fan PCB 106 Outdoor unit fan motor high current. Check fans rotate freely, and are connected correctly 107 Outdoor unit low voltage to fan PCB. Check 300 Vdc supply, check fuses and plug connections. If OK, replace fan PCB 108 Communication error between outdoor main PCB, and fan PCB. Check plug connections and LEDs. If OK replace either main or fan PCB 109 Sub 1 excessive rise of high pressure. Check pressures, check for non condensables, check heat exchanger coil is free from debris 110 Sub 1 reverse or open phase. Check all 3 phases are present and correct. If correct voltage appears at all three phases, swap any two to cure the fault 111 Communication error between Main and Sub outdoor units. Check comms wiring and power to all outdoor units 113 Main outdoor unit liquid pipe sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C 114 Main outdoor unit Subcool inlet sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C 115 Main outdoor unit Subcool outlet sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C 116 Sub 1 high pressure sensor fault. Check dc voltage between white and black cable on plug. Multi V: 1 Vdc = 8 bar up to 2.5 Vdc = 37 bar 117 Sub 1 low pressure sensor fault. Check dc voltage between white and black cable on plug. Multi V: 1 Vdc = 4 bar up to 5 Vdc = 32 bar 118 Sub 1 outdoor unit air sensor fault. Disconnect from PCB and measure resistance. 8 kOhm at 30°C and 13 kOhm at 20°C. If OK replace PCB, if not replace sensor 120 Sub 1 outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. if not replace sensor 121 Sub 1 compressor 1 discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20°C and 168 kOhm at 30°C. if not replace sensor 122 Sub 1 compressor 2 discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20°C and 168 kOhm at 30°C. if not replace sensor 123 Sub 1 outdoor unit coil sensor A fault. Disconnect from PCB measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace sensor 124 Sub 1 outdoor unit coil sensor B fault. Disconnect from PCB measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace sensor 125 Sub 1 outdoor unit liquid pipe sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C 126 Sub 1 outdoor unit Subcool inlet sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C 127 Sub 1 outdoor unit Subcool outlet sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C 128 Sub 2 high pressure sensor fault. Check dc voltage between white and black cable on plug. Multi V: 1 Vdc = 8 bar up to 2.5 Vdc = 37 bar 129 Sub 2 low pressure sensor fault. Check dc voltage between white and black cable on plug. Multi V: 1 Vdc = 4 bar up to 5 Vdc = 32 bar 130 Sub 2 outdoor unit air sensor fault. Disconnect from PCB and measure resistance. 8 kOhm at 30°C and 13 kOhm at 20°C. If OK replace PCB, if not replace sensor 132 Sub 2 outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C.if not replace sensor 133 Sub 2 compressor 1 discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20°C and 168kOhm at 30°C. if not replace sensor 134 Sub 2 compressor 2 discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20°C and 168kOhm at 30°C.if not replace sensor 135 Sub 2 outdoor unit coil sensor A fault. Disconnect from PCB measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace sensor 136 Sub 2 outdoor unit coil sensor B fault. Disconnect from PCB measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace sensor 137 Sub 2 outdoor unit liquid pipe sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C 138 Sub 2 outdoor unit Subcool inlet sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C 139 Sub 2 outdoor unit Subcool outlet sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C 140 Sub 2 excessive rise of high pressure. Check pressures, check for non condensables, check heat exchanger coil is free from debris 141 Sub 2 reverse or open phase. Check all 3 phases are present and correct. If correct voltage appears at all three phases, swap any two to cure the fault 142 Communication error between Main and Sub outdoor units. Check comms wiring and power to all outdoor units 143 Sub 1 excessive rise of high pressure. Check pressures, check for non condensables, check heat exchanger coil is free from debris 144 Sub 1 excessive drop of low pressure. Check pressures, check for non condensables, check heat exchanger coil is free from debris 145 Sub 2 excessive rise of high pressure. Check pressures, check for non condensables, check heat exchanger coil is free from debris 146 Sub 2 excessive drop of low pressure. Check pressures, check for non condensables, check heat exchanger coil is free from debris 147 Sub 1 check power supply voltage to the outdoor unit is correct (1ph 220 Vac ±10% or 3ph 380 Vac ±10%).check fuses, if fuses OK replace outdoor main PCB 148 Sub 1 check power supply voltage to the outdoor unit is correct (1ph 220 Vac ±10% or 3ph 380 Vac ±10%). check fuses, if fuses OK replace outdoor main PCB 149 Sub 2 check power supply voltage to the outdoor unit is correct (1ph 220 Vac ±10% or 3ph 380 Vac ±10%). check fuses, if fuses OK replace outdoor main PCB 150 Sub 2 check power supply voltage to the outdoor unit is correct (1ph 220 Vac ±10% or 3ph 380 Vac ±10%). check fuses, if fuses OK replace outdoor main PCB 151 Faulty 4 way valve. Check solenoid coil and output from PCB. If OK, mechanical failure. 152 Excessive discharge temperature rise 105°C Sub condenser 2 standard compressor. Check refrigerant 153 Excessive discharge temperature rise 105°C Sub condenser 2 standard compressor. Check refrigerant 154 Sub 3 excessive rise of high pressure. Check pressures, check for non condensables, check heat exchanger coil is free from debris 155 Sub 3 reverse or open phase. Check all 3 phases are present and correct. If correct voltage appears at all three phases, swap any two to cure the fault 156 Communication error between Main and Sub outdoor units. Check comms wiring and power to all outdoor units 157 Sub 3 high pressure sensor fault. Check dc voltage between white and black cable on plug. Multi V: 1 Vdc = 8 bar up to 2.5 Vdc = 37 bar 158 Sub 3 low pressure sensor fault. Check dc voltage between white and black cable on plug. Multi V: 1 Vdc = 4 bar up to 5 Vdc = 32 bar 159 Sub 3 outdoor unit air sensor fault. Disconnect from PCB and measure resistance. 8 kOhm at 30°C and 13 kOhm at 20°C. If OK replace PCB, if not replace sensor 161 Sub 3 outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. if not replace sensor 162 Sub 3 compressor 1 discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20°C and 168 kOhm at 30°C. if not replace sensor 163 Sub 3 compressor 2 discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20°C and 168 kOhm at 30°C.if not replace sensor 164 Sub 3 outdoor unit coil sensor A fault. Disconnect from PCB measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace sensor 165 Sub 3 outdoor unit coil sensor B fault. Disconnect from PCB measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace sensor 166 Sub 3 outdoor unit liquid pipe sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C 167 Sub 3 outdoor unit Subcool inlet sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C 168 Sub 3 outdoor unit Subcool outlet sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C 169 Sub 3 excessive rise of high pressure. Check pressures, check for non condensables, check heat exchanger coil is free from debris 170 Sub 3 excessive drop of low pressure. Check pressures, check for non condensables, check heat exchanger coil is free from debris 171 Sub 3 check power supply voltage to the outdoor unit is correct (1ph 220 Vac ±10% or 3ph 380 Vac ±10%). check fuses, if fuses OK replace outdoor main PCB 172 Sub 3 check power supply voltage to the outdoor unit is correct (1ph 220 Vac ±10% or 3ph 380 Vac ±10%). check fuses, if fuses OK replace outdoor main PCB 173 Main outdoor unit standard compressor not starting. Check output from main PCB, check contactor, and check wiring connections. If OK compressor faulty 174 Sub 1 standard compressor 1 not starting. Check output from main PCB, check contactor, and check wiring connections. If OK compressor faulty 175 Sub 1 standard compressor 2 not starting. Check output from main PCB, check contactor, and check wiring connections. If OK compressor faulty 176 Sub 2 standard compressor 1 not starting. Check output from main PCB, check contactor, and check wiring connections. If OK compressor faulty 177 Sub 2 standard compressor 2 not starting. Check output from main PCB, check contactor, and check wiring connections. If OK compressor faulty 204 Comms Error between Outdoor Unit and HR Box No1. 1. Defective connection in HR unit power supply and transmission connection 2. Wrong setting of the HR unit Rotary switch and Dip switch 3. Defective HR unit PCB 208 Comms Error between Outdoor Unit and HR Box No2. 1. Defective connection in HR unit power supply and transmission connection 2. Wrong setting of the HR unit Rotary switch and Dip switch 3. Defective HR unit PCB 212 Comms Error between Outdoor Unit and HR Box No3. 1. Defective connection in HR unit power supply and transmission connection 2. Wrong setting of the HR unit Rotary switch and Dip switch 3. Defective HR unit PCB 240 Central controller wiring error. Check all comms wiring, including between controller and CNU, and IP addresses. If OK possible defective CNU 241 Central controller data sending error. Either defective CNU or Central controller initialisation failure 242 Central controller data receiving error. Either defective CNU or Central controller initialisation failure 243 Central controller. Comms cable too long or picking up external electrical noise. If OK, mismatching of controllers, or defective CNU 244 Central controller data receiving time out. Either defective CNU or Central controller initialisation failure 245 Central controller data sending time out. Either defective CNU or Central controller initialisation failure 246 Central controller data receiving time out. Either defective CNU or Central controller initialisation failure 250 Central controller data receiving error. Either comms cable picking up external electrical noise, or defective CNU 251 Central controller receiving no data. Either comms cable picking up external electrical noise, or defective CNU 252 Central controller incorrect address error. Check addresses match, if OK either comms cable picking up external electrical noise, or defective CNU 253 Central Controller Disconnection Error, No response from Air Conditioner. Check wiring, if OK either comms cable picking up external electrical noise, defective CNU, or Interface. C1 Indoor unit return air sensor fault, Open or Short. Disconnect sensor from PCB and measure resistance. 8 kOhm at 30C and 13 kOhm at 20C if not replace sensor C2 Indoor Pipe Sensor or Outdoor Sensor Assy fault, Open or Short. Disconnect from PCB and measure resistance. Air sensor = 10 kOhm at 25C, Pipe sensor = 5 kOhm at 25C. If not replace sensor. C4 RAC Product = Heat Sink Sensor Error, Open/Short Cct or over 95C. Commercial Product = Condensate pump float switch risen. Check drain pan is empty, check pump is working OK. If no pump check blue jumper plug is inserted in socket CN Float. C5 Comms Error, check your wiring, remove external pumps. Split/Multi — check volts from terminal N to 3 = 0 — 65 Vdc, Multi V — 4 Vdc terminals 3 and 4 C6 Inverter compressor run current high. Check compressor windings all equal 1 to 4 Ohms, Check to earth 50 MOhm minimum, check run current C7 Splits = Compressor Over Current (CT2), also see Code 06. RAC Indoor unit BLDC Fan problem. This is caused by the Indoor fan being locked. Check fan motor is plugged in correctly, Electrically & Mechanically sound. C8 Check the fan motor turns freely, check the AC Voltage supplied to the fan motor, this will vary from 120 V ac at low speed to 170V AC at high speed. If no Voltage is present the the PCB is faulty, if Voltage is present the fan motor will be Faulty. C9 Outdoor unit fan problem. Check Outdoor fan motor is plugged in, Electrically & Mechanically sound, if not replace motor, otherwise replace PCB. CA Compressor discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20°C, 168 kOhm at 30C. CC RAC Product = EEPROM Sum Check Error, text 60 for help. Cd RAC Product = PSC (Reactor) Error, text 27 for help. CE RAC Product = Compressor Phase Current Error CH00 Text the 1, 2 or 3 digit fault code number only. I.e. If you see fault code CH07 on your indoor unit or R/Controller, only type 7 or 07 in your text message. CH01 Indoor unit return air sensor fault. Disconnect sensor from PCB and measure resistance. 8 kOhm at 30C and 13 kOhm at 20C if not replace sensor CH02 Indoor Pipe Sensor or Outdoor Sensor Assy fault, Open or Short. Disconnect from PCB and measure resistance. Air sensor = 10 kOhm at 25C, Pipe sensor = 5 kOhm at 25C. If not replace sensor. CH03 Remote controller comms error. Check wired correctly, if so check dipswitch in RC. Set to Sg for 1 unit, or Gr for group then reset power CH04 RAC Product = Heat Sink Sensor Error, Open/Short Cct or over 95C. Commercial Product = Condensate pump float switch risen. Check drain pan is empty, check pump is working OK. If no pump check blue jumper plug is inserted in socket CN Float. CH05 Comms Error, check your wiring, remove external pumps. Split/Multi — check volts from terminal N to 3 = 0 — 65 Vdc, Multi V — 4 Vdc terminals 3 and 4 CH06 Indoor unit coil sensor fault. Disconnect from PCB measure resistance. 10 kOhm at 10C and 4 kOhm at 30C. if not replace sensor. Split = text 21 CH07 Multi Splits and Multi V = indoor unit is set to run in a different mode from the master indoor unit. Set ALL indoor units to cooling or ALL to heating to clear. Splits = Compressor Over Current (CT2), also see Code 06. RAC Indoor unit BLDC Fan problem. This is caused by the Indoor fan being locked. Check fan motor is plugged in correctly, Electrically & Mechanically sound. CH08 Check the fan motor turns freely, check the AC Voltage supplied to the fan motor, this will vary from 120 V ac at low speed to 170V AC at high speed. If no Voltage is present the the PCB is faulty, if Voltage is present the fan motor will be Faulty. CH09 Split = Outdoor unit fan problem. Check Outdoor fan motor is plugged in, Electrically & Mechanically sound, if not replace motor, otherwise replace PCB. Multi V = indoor PCB failure. Replace PCB CH10 RAC Product: Compressor discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20°C, 168 kOhm at 30C. Multi Fdx & Multi V text 8 CH11 Multi V indoor unit not connected to an outdoor unit. Check comms wiring is correct, and check initialisation has been carried out correctly CH12 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH13 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH14 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH15 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH16 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH17 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH18 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH19 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH20 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH21 Inverter compressor run current high. Check compressor windings all equal 1 to 4 OhmsCheck to earth 50 MOhm minimum, check run current CH22 Inverter compressor run current high. Check compressor windings all equal 1 to 4 Ohms . Check to earth 50 MOhm minimum, check run current CH23 Inverter dc voltage low. Check dc voltage of capacitors 300 Vdc for 1Ph and 600 Vdc for 3Ph. If OK change outdoor inverter PCB CH24 Splits and Multi Splits = High or low pressure trip. Low at 1 bar High at 35 bar check pressures. Multi V = High pressure trip. CH25 Check power supply voltage to the outdoor unit is correct (1ph ?220 Vac ±10% or 3ph ?380 Vac ±10%). If OK, check fuses, if fuses are OK replace outdoor main PCB CH26 Inverter compressor seized. Check compressor windings all equal resistance 1 to 4 Ohms, check to earth 50 MOhm minimum, check run current and Inverter outputs CH27 Inverter current irregularity. Check inverter PCB and reactor CH28 Inverter dc voltage too high. Check dc voltage of capacitors 300 Vdc for 1Ph and 600 Vdc for 3Ph. If OK change outdoor inverter PCB CH29 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH30 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH31 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH32 Inverter compressor discharge temperature too high. If over 105°C, check refrigerant charge CH33 Excessive rise of standard compressor discharge temperature. If over 105°C check refrigerant charge CH34 Excessive high pressure rise, over 35 bar at HP sensor. Check pressures, check coils, and filters are clean check for OFN in system pipework CH35 Excessive low pressure drop under 1 Bar at LP sensor. Check pressures, and check service valves open CH36 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH37 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH38 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH39 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH40 Inverter ac current abnormal. Check compressor windings all equal resistance 1 to 4 Ohms, check to earth 50 MOhm minimum, check run current and inverter outputs CH41 Inverter compressor discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20C and 168 kOhm at 30C. CH42 Low pressure sensor fault. Check dc voltage between white and black cable on plug. Multi V: 1 Vdc = 4 bar up to 5 Vdc = 32 bar CH43 High pressure sensor fault. Check dc voltage between white and black cable on plug. Multi V: 1 Vdc = 8 bar up to 2.5 Vdc = 37 bar CH44 Outdoor unit air sensor fault. Disconnect from PCB and measure resistance. 8 kOhm at 30°C and 13 kOhm at 20°C. If OK replace PCB, if not replace sensor CH45 Outdoor unit coil sensor fault. Disconnect from PCB measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace sensor CH46 Outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace sensor CH47 Compressor discharge sensor fault. Disconnect from PCB measure resistance. 237 kOhm at 20°C and 168 kOhm at 30°C. If OK replace PCB, if not replace sensor CH48 Split/Multi Split = Outdoor unit discharge and air sensor both unplugged. Multi V = Outdoor unit coil sensor. Text 45 for diagnostics CH49 Check power supply voltage to the outdoor unit is correct (1ph ?220 Vac ±10% or 3ph ?380 Vac ±10%). If OK check fuses, if fuses OK, replace outdoor main PCB CH50 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH51 Unit mismatch. Check model number of units do not exceed maximum. Multi V — also check Sub outdoor unit dipswitch settings CH52 Communication error between inverter PCB and main outdoor unit PCB. Check wiring fuses and LEDs . If OK either inverter or main PCB defective CH53 Comms error indoor to outdoor unit. Check your wiring . Split and Multi — check voltage from terminal N to 3 = 0 — 65 Vdc, Multi V — 4 Vdc terminals 3 and 4 CH54 Reverse or open phase. Check all 3 phases are present and correct. If correct voltage appears at all three phases, swap any two to cure the fault CH55 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH56 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH57 Comms error between outdoor main PCB and inverter PCB. Check wiring fuses and LEDs are lit. If OK either inverter or main PCB defective CH58 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH59 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH60 Outdoor unit PCB EEPROM failure, try removing EEPROM and refitting if removable (possible contact fault), otherwise replace PCB if the EEPROM is non-removable. CH61 Condenser coil over 65°C. Check coil and filters are clean and free from debris, and airflow is OK. Check system pressures for non-condesables CH62 Inverter over 85°C. Check air flow across heat sink, check inverter tight to heatsink use thermal paste. Multi V — check inverter cooling fan CH63 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH64 no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message CH65 Outdoor unit inverter fin temperature sensor fault. Disconnect from PCB measure resistance. 8 kOhm at 30°C and 13 kOhm at 20°C CH67 Outdoor Fan Motor siezed, or rotation sensing circuit failure. Check motor for mechanical and electrical failure. CL CL = Child Lock. Press Timer & Min buttons simultaneously for 5 seconds to engage/disengage function. help Text the 1, 2 or 3 digit fault code number only. I.e. If you see fault code CH07 on your indoor unit or R/Controller, only type 7 or 07 in your text message. HL Condensate pump float switch risen. Check drain pan is empty, check pump is working OK. If no pump check blue jumper plug is inserted in socket CN Float. Alternatively, Dry Contact Interface is in «OFF» condition. Check status and adjust as necessary. Po Po = Jet Cool Mode selected. To cancel press Jet Cool, Fan Speed or Set Temperature button.

Коды ошибок кондиционеров позволяют сервисному инженеру быстро найти и качественно устранить неисправности.

Диагностика кондиционера

Это первое, что необходимо сделать перед его обслуживанием или ремонтом. Диагностика кондиционера позволяет выявить поломки и неисправности в системе. Будь то недостаток хладагента, который необходимо восполнить, ошибки в алгоритме работы кондиционера или неисправности основных узлов.

Своевременная и грамотная диагностика неполадок позволит сервисному инженеру быстро и качественно устранить неисправности. А значит, вернуть в дом или офис клиента здоровый микроклимат.

Все современные кондиционеры имеют развитую систему самодиагностики. В результате анализа состояния оборудования система выявляет причину возникшей неисправности и выводит код ошибки на дисплей (пульта, платы или индикатора режимов). Ниже приведены коды ошибок кондиционеров (alarm code) различных марок. Используя данную информацию, можно самостоятельно считать код ошибки и выполнить ремонт кондиционера. Это значительно сэкономит время диагностики оборудования и позволит избежать неточности в определении характера и места поломки.

Коды ошибок кондиционеров

Мы подобрали для вас информацию о кодах ошибок кондиционеров и сплит-систем разных брендов.

Если нужен авторизованный сервисный центр по ремонту кондиционеров — это к нам! Компания ЕВРОБИЗНЕС — ваш надежный партнер!

Коды ошибок кондиционеров Beko BKN, AKN

Неисправность кондиционера Running Sleeping Timer
Ошибка  термодатчика испарителя
Ошибка комнатного термодатчика 2
Ошибка термодатчика конденсатора 3
Неправильная  работа внутреннего двигателя вентилятора 2

⊕ — мигает, 2 — горит, 3 — не горит. Если есть данные ошибки, то работа кондиционера будет автоматически прекращена.

Коды ошибок кондиционеров Beko AKH, AKP, AS, BKH, BKP, BS

Код ошибки Неисправность кондиционера
F1 или FF01 Неправильная работа испарителя
F3 или FF03 В режиме охлаждения высокая температура конденсатора. Автоматическое отключение.
F4 или FF04 В режиме нагрева высокая температура конденсатора. Автоматическое отключение.
F6 или FF06 Неправильная работа внутреннего двигателя вентилятора
F7 или FF07 Ошибка комнатного термодатчика
F8 или FF08 Ошибка термодатчика испарителя
F9 или FF09 Ошибка термодатчика конденсатора

Коды ошибок кондиционеров Beko инверторного типа BKC 090 INV, BKC 120 INV, BKL090 INV, BKL120 INV

Код ошибки Неисправность кондиционера
E1 Ошибка комнатного датчика температуры
E2 Ошибка термодатчика испарителя
E3 Ошибка в работе двигателя
E5 Ошибка сигнала связи между внутренним и внешним блоком
1E Ошибка внешнего датчика температуры
2E Ошибка термодатчика конденсатора

Если не работает кондиционер BEKO — это к нам!

Коды ошибок кондиционеров Carrier

Если обнаружена неисправность, то зеленый индикатор (Р) и оранжевый индикатор (R) мигают с частотой 0,1 сек, показывая код неисправности. Следует заметить, что оранжевый индикатор (R) соответствует десяткам в числе — коде неисправности. Зеленый индикатор (Р) соответствует единицам в числе — коде неисправности.
Между миганиями оранжевого и зеленого индикаторов проходит 2 секунды. Последовательность повторяется с интервалом 4 сек.

Например, код неисправности 13. Оранжевый индикатор мигает один раз, оба индикатор выключены 2 секунды, зеленый индикатор мигает три раза с интервалом в 0,5 секунды, оба индикатор выключены 4 секунды.
Последовательность повторяется, пока неисправность не будет устранена. Если код неисправности меньше 10, то оранжевый индикатор не мигает.

Код Описание
2 Неисправность датчика температуры в помещении
3 Неисправность датчика температуры внутреннего теплообменника Тс
6 Неисправность реверсивного клапана наружного блока
8 Неисправность двигателя вентилятора во внутреннем блоке
9 Не подается электропитание на внутренний блок
11 Неисправность дренажной помпы или другие проблемы с дренажом
12 Ошибка в программном обеспечении внутреннего блока (неправильная адресация)
13 Ошибка конфигурации
14 Потеря сигнала центральной системы управления
15 Неисправность датчика температуры внутреннего теплообменника Tcj
18 Неисправность блока управления наружного блока (защита от короткого замыкания G-Tr)
20 Ошибка в контуре распознавания положения блока
21 Неисправность датчика тока в наружном блоке
22 Неисправность датчика температуры наружного теплообменника
23 Неисправность датчика температуры нагнетания
24 Неисправность вентилятора наружного блока
26 Другая неисправность наружного блока
27 Заблокирован компрессор наружного блока
27 Недопустимая температура нагнетания
29 Неисправность компрессора наружного блока
31 Повышенное давление в контуре наружного блока

Если не работает кондиционер CARRIER — это к нам!

Коды ошибок кондиционеров Chigo

Код ошибки Причина неисправности
E1 Нет связи между внутренним и внешним блоками
E2 Датчик комнатной температуры
E3 Датчик температуры испарителя
E4 Защита по низкому давлению
E7 Неправильное чередование фаз
E8 Защита от перегрева / обмерзания
E9 Ошибка в работе внешнего блока

Если не работает кондиционер CHIGO — это к нам!

Коды ошибок кондиционеров Daewoo

Код ошибки Причина неисправности
F6 PG motor faults
F7 Indoor TEMP sensor faults
F8 Indoor coil pipe TEMP sensor faults
F9 Outdoor coil pipe TEMP sensor faults

Если не работает кондиционер Daewoo — это к нам!

Коды ошибок кондиционеров Fujitsu General

Корпорация Fujitsu General Ltd. представила на рынке новый продукт для диагностики сплит-систем и мульти-сплит-систем GENERAL. Инструмент представляет собой комплект из адаптера, соединяющего наружный блок с компьютером, и программу для ПК. С их помощью специалист, проводящий диагностику оборудования, в режиме реального времени может видеть параметры работы компрессора, мотора вентилятора, EEV, показания датчиков, а также журнал ошибок. В процессе тестирования возможна запись рабочего журнала с выдачей отчета.

Адаптер подходит для работы с мульти-сплит-системами, а также с большинством инверторных сплит-систем (настенных, потолочных, канальных, кассетных).

Современные кондиционеры Fujitsu General имеют очень развитую систему самодиагностики, по результатам которой система управления при обнаружении той или иной неисправности блокирует работу всего аппарата и одновременно сообщает о причине неисправности.

Система управления кондиционеров Fujitsu General сообщает о возникших неисправностях посредством мигания светодиода на панели внутреннего (в некоторых случаях наружного) блока. При обнаружении той или иной неисправности кондиционера светодиоды горят или мигают в определенной последовательности, что соответствует выявленной ошибке. Если система управления кондиционера обнаружила более одной ошибки, то сначала индицируется неисправность, имеющая наибольший приоритет, а затем все остальные.

Коды ошибок неисправностей кондиционеров Fujitsu General приведены в таблице.
Причина неисправности Дисплей ошибок
OPERATION (red) TIMER (green) SWING (orange)
Неисправность платы внутреннего блока О О
Разомкнут провод датчика температуры в помещении (внутренний блок) 2 X О
Короткое замыкание в цепи датчика температуры в помещении (внутренний блок) 2 X О О
Разомкнут провод датчика трубопровода внутреннего блока 3 X О
Короткое замыкание в цепи датчика трубопровода внутреннего блока 3 X О О
Неисправен вентилятор внутреннего блока 6 X О

Для некоторых моделей (см. список *) в зависимости от ошибки индикаторы OPERATION, TIMER, SWING работают по следующему принципу: О — быстрое мигание; X — медленное мигание; ВЫКЛ.

* Внутренний блок: ASG18FBAJ, ASG18FBBJ, ASG18UBAJ, ASG18UBBJ, ASG24FBBJ, ASG30FBBJ, ASG18FBBX, ASG18UBBN, ASG24FBBN, ASG24UBBN, AWG18FBAJ, AWG18FBBJ, AWG18UBAJ, AWG18UBBJ, AWG24FBBJ, AWG24UBBJ, AWG30FBBJ, AWG30UBBJ, AWG14UBBJ, ABG14FBBJ, ABG14FBBJ, ABG18FBBJ, ABG18FBBJ, ABG181BBJ, ABG181BBJ, ABG24FBBJ, ABG24FBBJ, ABG241BBJ, ABG241BBJ, AWG24FBAJ, AWG24UBAJ.
* Внешний блок: AOG18FNAK, AOG18FNBK, AOG18UNAKL, AOG18UNBKL, AOG24FNBK, AOG24UXBKL, AOG30UNBDL, AOG18FNBX, AOG18UXBXL, AOG24FXBX, AOG24UXBXL, AOG18FNAK, AOG18FXBK, AOG18UNAKL, AOG18UXBKL, AOG24FNBK, AOG24UXBKL, AOG30FNBDL, AOG30UNBDL, AOG14USBJ, AOG14FNBK, AOG14FXBX, AOG18FNBK, AOG18FXBX, AOG18UXBKL, AOG18UNBNL, AOG24FNBK, AOG24FXBX, AOG241XBKL, AOG24UXBXL, AOG24FXAD, AOG24UXADL

Если не работает кондиционер Fujitsu General — это к нам!

Коды ошибок кондиционеров Haier

Ремонт кондиционеров HAIER (ХАЙЕР) выполняется на основе анализа рабочих параметров устройств и кодов неисправностей.

Если ошибки и неисправности отсутствуют, но блок при этом не запускается, возможно, условия запуска не соответствуют требуемым. В этом случае на дисплее ведущего блока будут отображаться следующие резервные коды:

555 Ждущий режим при предельных значениях производительности. Если общая производительность подключенных блоков превышает 130% или составляет менее 50%, то система переходит в ждущий режим.
555.1 Режим обогрева при слишком высокой температуре наружного воздуха. Если Тout > 27°С, то система находится в ждущем режиме.
555.3 Режим охлаждения при слишком высокой или низкой температуре наружного воздуха. Если Тout > 54°С или < -10°С, то система находится в ждущем режиме.
555.4 Работа нагревателя картера компрессора. Слишком низкая температура масла.

Коды ошибок и неисправностей внутренних блоков кондиционеров HAIER

Индикация на дисплее пульта Кол-во вспышек LED5 / Timer Описание неисправности
01 1 Неисправность датчика температуры окружающего воздуха Tai
02 2 Неисправность датчика температуры теплообменника ТС1
03 3 Неисправность датчика температуры теплообменника ТС2
04 4 Неисправность датчика температуры двойного энергоисточника
05 5 Ошибка EEPROM платы внутреннего блока
06 6 Отсутствие связи между внутренним и наружным блоками
07 7 Отсутствие связи между внутренним блоком и проводным пультом
08 8 Ошибка отвода конденсата
09 9 Дублирование адреса внутреннего блока
10 Дублирование центрального адреса внутреннего блока
Коды неисправности внешнего блока 20 Соответствующая неисправность внешнего блока

Коды ошибок и неисправностей инверторного наружного блока

Индикация на дисплее пульта Код ошибки Описание неисправности
20-0 Ошибка по датчику t защиты от обмерзания ТЕ1 Значение AD меньше 11 (контур разомкнут) или больше 1012 (контур замкнут) более 60 сек. в режиме охлаждения, если датчик неисправен, блок не использует его показания, за исключением функции оттаивания или в течение 3 мин. после ее окончания; сигнал тревоги отсутствует
20-1 Ошибка по датчику t защиты от обмерзания TE2
21 Ошибка датчика температуры наружного воздуха Та Значение AD меньше 11 (контур разомкнут) или больше 1012 (контур замкнут) более 60 сек. в режиме оттаивания или в течение 3 мин. после его окончания; сигнал тревоги отсутствует.
22 Ошибка по датчику температуры всасывания Ts Значение AD меньше 11 (контур разомкнут) или больше 1012 (контур замкнут) более 60 сек. в режиме оттаивания или в течение 3 мин. после его окончания; сигнал тревоги отсутствует.
23 Ошибка по датчику температуры нагнетания Td После 5-ти минутной работы компрессора значение AD меньше 11 (контур разомкнут) или больше 1012 (контур замкнут) более 60 сек. во время запуска, в режиме оттаивания или в течение 3 мин. после его окончания; сигнал тревоги отсутствует
24 Ошибка по датчику температуры масла Toil Значение AD меньше 11 (контур разомкнут) или больше 1012 (контур замкнут) более 60 сек., (контур замкнут) в течение 60 сек; если в течение 5 минут Та 2 -10°С или ЕТ < -10®С, сигнала тревоги нет.

В таблицах представлены лишь некоторые коды неисправностей кондиционеров HAIER. Напоминаем, что кондиционеры HAIER представляют собой технически сложное оборудование. Коды ошибок предусмотрены для квалифицированных и сертифицированных специалистов. То есть, для тех, кто профессионально занимается ремонтом кондиционеров HAIER, а не для обычных пользователей. Доверяйте ремонт кондиционеров HAIER профессионалам.

Если не работает кондиционер Haier- это к нам!

Коды ошибок кондиционеров Hisense

При возникновении неисправности нажмите 4 раза кнопку Sleep на пульте ДУ — на 7-сегментном дисплее загорится код ошибки (см. таблицу ниже). Если несколько ошибок, то снова нажмите 4 раза кнопку Sleep — загорится светодиодный индикатор со следующим кодом ошибки.

Обновленный пульт дистанционного управления, который имеет 4 режима работы кнопки «Sleep», позволяет установить 4 разных комбинации. При его использовании для проверки кодов ошибок необходимо нажать на кнопку «Sleep» 10 раз. После этого начнут отображаться коды ошибок.

Код Причина неисправности
1 Ошибка датчика температуры теплообменника наружного блока
2 Ошибка датчика температуры в линии нагнетания компрессора
5 Срабатывание защиты интегрального силового модуля (IPM)
6 Срабатывание устройства защиты от повышенного или пониженного напряжения в сети переменного тока
7 Ошибка связи между внутренним и наружным блоками
8 Устройство защиты от перегрузок
10 Ошибка связи между двумя микросхемами (управления и привода) в печатной
11 Ошибка памяти ЭСППЗУ наружного блока
12 Срабатывание устройства защиты при низких температурах наружного воздуха
13 Срабатывание устройства защиты в результате повышенной температуры в
14 Ошибка датчика температуры наружного воздуха
15 Срабатывание тепловой защиты компрессора по перегреву
16 Срабатывание устройства защиты теплообменника от обмерзания или перегрузок при работе внутреннего блока в режиме обогрева
17 Устройство компенсации реактивной мощности (PFC)
18 Ошибка запуска компрессора постоянного тока
19 Ошибка привода компрессора

Коды ошибок кондиционеров IGC

Код Индикатор работы Описание ошибки
E1 Мигает 1 раз Неисправен датчик температуры в помещении
E2 Мигает 2 раза Неисправен датчик температуры трубный
E6 Мигает 6 раз Отказ электродвигателя вентилятора indoor unit
IMS MINI (IMS-EM080NH, IMS-EM100NH, IMS-EM120NH, IMS-EM140NH, IMS-EM160NH)
Код Неполадка
СН Неисправность термистора жидкостной трубы
CJ Неисправность датчика температуры
E6 Ограничения частоты защиты температуры на трубке всасывания «TS»
E7 Ограничения частоты защиты средней температуры внешнего конденсатора
E8 Защитная остановка внешнего конденсатора
E9 Ограничения частоты компрессора по сверхвысокой температуре
F4 Неполадки датчика низкого давления
F5 Ограничения защиты датчика низкого давления для сверхвысокой или ультра низкой частоты
F6 Защитная остановка по датчику низкого давления для сверхвысокой или ультранизкой частоты
H8 Защита от перегрузки по току компрессора с постоянной частотой 1
H9 Защита от перегрузки по току компрессора с постоянной частотой 2
НА Защита от перенапряжения и недонапряжения входного напряжения
НС Неправильная последовательность фаз компрессора с постоянной частотой 1
HH Неправильная последовательность фаз частотного преобразователя компрессора
HJ Неправильная последовательность фаз компрессора с постоянной частотой 2
J4 Ошибка связи с панелью управления и двигателем вентилятора
J5 Ошибка установки адреса или настроек нагрузки внешнего блока
38 Ограничения частоты защиты температуры радиатора
39 Защитная остановка радиатора
Защита вентилятора постоянного тока
Защита от перенапряжения вентилятора постоянного тока
Ошибка включения или асинхронный режим работы вентилятора
3J Защита от перепадов напряжения вентилятора постоянного тока

Коды ошибок кондиционеров Kentatsu

Коды ошибок Kentatsu KSVP-HF

E2 — неисправность датчика комнатной температуры
EЗ — неисправность датчика температуры испарителя
E4 — неисправность датчика температуры наружного блока
E6 — неисправность наружного блока
E7 — ошибка EEPROM
E8 — превышение уровня воды

Коды ошибок Kentatsu KSKT-HF канального типа

E0 — неисправен датчик комнатной температуры
E1 — неисправен датчик температуры испарителя
E2 — неисправен датчик температуры наружного блока
E3 — неисправен наружный блок
E4 — неисправен датчик температуры дренажного насоса
E5 — ошибка EEPROM
E6 — повышение уровня воды

Коды ошибок Kentatsu KSFU модели: KSFU/KSRU76HFDN3, KSFU/KSRU140HFDN3

P4 — тепловая защита испарителя внутреннего блока
P5 — тепловая защита конденсатора внешнего блока
P9 — защита функции разморозки или создания комфортного потока воздуха
E1 — обрыв или короткое замыкание цепи датчиков температуры Т1
E2 — датчик температуры испарителя Т2 замкнут/оборван
E3 — датчик температуры конденсатора Т3 замкнут/оборван
E6 — защита наружного блока

Коды ошибок Kentatsu KSGH/KSRH

Модели: KSGH/KSRH21CFDN1 KSGH/KSRH26CFDN1, KSGH/KSRH35CFDN1 KSGH/KSRH53CFDN1, KSGH/KSRH21HFDN1 KSGH/KSRH26HFDN1, KSGH/KSRH35HFDN1 KSGH/KSRH53HFDN1
E1 — ошибка EEPROM (энергонезависимая память на плате)
E2 — ошибка перехода через ноль (zero crossing error)
EЗ — аномальная скорость вентилятора
E4 — токовая защита компрессора сработала 4 раза
E5 — датчик температуры внутреннего воздуха замкнут/оборван
E6 — датчик температуры испарителя замкнут/оборван

Коды ошибок Kentatsu напольного типа KSFU70XFAN1 /KSRU70HFAN1, KSFU120XFAN3 / KSRU120HFAN3

P4 — защита по температуре испарителя
P5 — защита по температуре конденсатора
P7 — температура нагнетания слишком высока.включена защита компрессора
P9 — слишком низкая температура наружного воздуха, при повышении защита отключится автоматически
P10 — защита по выходному давлению
P11 — защита по давлению всасывания
P12 — защита от перегрузки по току
E1 — датчик температуры внутреннего воздуха Т1 замкнут/оборван
E2 — датчик температуры испарителя Т2 замкнут/оборван
E3 — датчик температуры конденсатора Т3 замкнут/оборван
E4 — датчик температуры наружного воздуха замкнут Т4 замкнут/оборван
E5 — нарушена связь между внутренним и внешним блоками
E6 — защита внешнего блока
E10 — ошибка по давлению всасывания компрессора
E13 — ошибка фазы компрессора
E14 — неправильная фазировка компрессора
HS — запуск размораживания

Если не работает кондиционер Kentatsu — это к нам!

Коды ошибок кондиционеров LG

Код Причина неисправности
F01 Обрыв/замыкание room комнатного (воздушного) датчика температуры внутреннего блока
F02 Обрыв/замыкание pipe датчика температуры внутреннего блока
F03 Отсутствие связи между пультом управления и основной платой управления более 2-х минут
F04 Обрыв/замыкание pipe датчика температуры внешнего блока
F05 Обрыв/замыкание room воздушного датчика температуры внешнего блока
CH01 Неисправность одного из терморезисторов платы (разрыв или короткое замыкание) внутреннего комнатного, настенного блока сплит системы — контроля температуры поступающего воздуха и трубки газового контура кондиционера
CH02 Неисправность одного из терморезисторов (разрыв или короткое замыкание) наружного блока: датчика температуры поступающего воздуха или температуры трубки газового контура
CH03 Кондиционер работает одновременно и на обогрев и на охлаждение воздуха
CH04 Включена система защиты компрессора от перегрузки
СН05 Ошибка обмена данными между комнатным и наружным блоками сплит-системы
СН06 Ток потребления одного или нескольких исполнительных устройств наружного блока-реле, кратковременно был выше нормы
CH07 Ток потребления всего наружного блока длительное время был выше нормы
СН08 Неисправность двигателя вентилятора
CH09 Неисправность 4-х ходового клапана
СН10 Неисправен терморезистор контроля температуры корпуса компрессора сплит системы (обрыв или короткое замыкание)

LGMV — это мобильное приложение, разработанное производителем для дистанционного мониторинга рабочих параметров систем кондиционирования LG. Приложение помогает инженерам оценивать текущее состояние оборудования. Анализ производится на основе многолетнего цикла эксплуатации. Программа помогает не только оперативно определять проблемы в работе системы, но и выдает рекомендации по решению вопроса.

Система диагностики LGMV обеспечивает контроль рабочих параметров системы, профилактику и предотвращение неисправностей системы. Все это безусловно упрощает диагностику и пуско-наладочные работы. LGMV состоит из беспроводного коммуникационного модуля и бесплатного смартфон-приложения. Для использования мобильного приложения LGMV требуется эксклюзивный модуль Bluetooth, соответствующий разъем которого необходимо подключить в порт CN-LGMV на основной плате наружного блока.

Основные функции LGMV:

Визуальное отображение ключевой информации о работе кондиционера.
Графическая индикация давления и др. параметров.
Контроль режима работы внутренних блоков, когда модуль подключен к наружному блоку.
Сохранение данных о работе кондиционера в виде файла.
Отчет о работе — результат операции тестирования формируется в HTML-документ.
Индикация номера ошибки и поддержка поиска ошибки в списке из PDF-документа.

Mobile LGMV можно скачать, например, в Google Play как продукт LG Electronics, Inc. в качестве инструмента для технического обслуживания, поиска и устранения неисправностей для систем кондиционирования LG. Мобильное приложение LGMV использует ограниченный ресурс на смартфоне и обрабатывает данные в режиме реального времени. Мониторинг данных может быть осложнен или данные не могут быть полностью сохранены, если производительность смартфона является низкой.

Рекомендуется использовать смартфон высокой производительности. Если системных ресурсов недостаточно из-за других включенных интернет-приложений, то помимо наблюдения в ходе мониторинга данных могут произойти сбои. Функция мониторинга и сохранение функции могут работать не в полном объеме. А также Bluetooth соединение связи может быть отключено. Кроме того, приложение может отключено из-за недостатка ресурсов или непредвиденной ошибки.

Уровень передачи данных может увеличиваться в зависимости от количества наружных и внутренних блоков. Расстояние передачи данных через Bluetooth может быть сокращено вплоть до отключения передачи данных в зависимости от погоды или состояния окружающей среды (электромагнитные волны или препятствие) и т.д. Рекомендуется использовать модуль Bluetooth на короткое расстояние.

Если не работает кондиционер LG — это к нам!

Коды ошибок кондиционеров MDV

Индикация ошибок на внутреннем блоке MDV
E0 Ошибка EEPROM
E1 Ошибка межблочного соединения
E2 Проблема правильности подключения фазы и ноля по блокам
E3 Ошибка скорости вращения мотора вентилятора внутреннего блока
E5 Ошибка по датчикам температур наружного блока
E6 Ошибка по датчикам температур внутреннего блока
P0 Сработала защита модуля инвертера
P1 Защита по высокому или низкому напряжению питания
P2 Защита по перегреву компрессора
P3 Защита от повышенного тока компрессора
P4 Защита модуля силового преобразователя
P5 Несоответствие режимов работы

Если требуется диагностика кондиционера MDV — это к нам!

Индикация ошибок на внешнем блоке MDV
Е0 Ошибка EEPROM
Е1 Ошибка по датчикам температур внутреннего блока 1
Е2 Ошибка по датчикам температур внутреннего блока 2
Е3 Ошибка по датчикам температур внутреннего блока 3
Е4 Ошибка по датчикам температур наружного блока
Е5 Защита по высокому или низкому напряжению питания
Е6 Ошибка по датчикам температур внутреннего блока 4
Е7 Нет связи между платами управления и инвертера
Р0 Защита по перегреву компрессора
Р1 Защита по высокому давлению — только для M4OCi
P2 Защита по низкому давлению — только для M4OCi
Р3 Защита от повышенного тока компрессора
Р4 Сработала защита модуля инвертера
Р5 Защита по низкой температуре наружного воздуха -7°C
P6 Защита по высокой температуре конденсации

Если не работает кондиционер MDV — это к нам!

Коды ошибок кондиционеров Mitsubishi Electric

Если не работает кондиционер Mitsubishi Electric — это к нам!

Коды ошибок кондиционеров Mitsubishi Heavy

Если не работает кондиционер Mitsubishi Heavy — это к нам!

Коды ошибок кондиционеров Wisnow

Код Индикация Неисправность
Е1 Мигает 1 раз Поврежден датчик измерения температуры воздуха в помещении
Е2 Мигает 2 раза Поврежден датчик измерения температуры испарителя в помещении
Е6 Мигает 6 раз Поврежден двигатель вентилятора внутреннего блока

Если не работает кондиционер Wisnow- это к нам!

Коды ошибок кондиционеров Polaris

Код ошибки Неисправность кондиционера
Е2 Воздушный температурный датчик неисправен
Е3 Температурный датчик радиатора внутреннего блока поврежден
Е4 Неисправность внешнего блока
Е5 Электродвигатель внутреннего блока неисправен
dF Кондиционер в режиме оттаивания

Если не работает кондиционер Polaris — это к нам!

Коды ошибок кондиционеров Sanyo

Описание неисправностей, которые индицируются на плате внешнего блока SANYO W-ECO MULTI SYSTEM. Справедливо для моделей SPW-CR1503GDYH8, SPW-CR1903GDYH8, SPW-CR703GDCH8, SPW-CR903GDCH8, SPW-C1503GDYH8, SPW-C1903GDYH8, SPW-C703GDCH8, SPW-C903GDCH8.

Если не работает кондиционер Sanyo — это к нам!

Коды ошибок кондиционеров Sharp

Например, индикация неисправностей в кондиционерах SHARP моделей AY-A184E / AE-A184E, AY-A244E / AE-A244E.

Если не работает кондиционер Sharp — это к нам!

Коды ошибок кондиционеров Toshiba

Код Неисправность
00-0с ошибка датчика температуры внутреннего воздуха или платы внутреннего блока
00-0d ошибка датчика температуры радиатора или платы управления
00-11 неисправна плата или двигатель вентилятора
00-12 необходима замена платы управления
01-04 сгорели предохранители на плате, неправильное межблочное соединение, сгорела плата
01-05 ошибка инверторной платы
02-14 перегрузка по току инвертера
02-16 замыкание между обмотками компрессора
02-17 ошибка датчика тока
02-18 ошибка датчиков температуры, платы PC
02-19 ошибка температурного датчика TD, платы PC
02-1a ошибка вентилятора внешнего блока — перегрузка по току, заблокирован, сгорел двигатель или плата
02-1b датчик температуры конденсора неисправен или плата
02-1c компрессор не запустился в течение 20 секунд
03-07 недостаток хладагента, ошибка инверторной платы
03-1d неисправен компрессор
03-1e ошибка датчика всасывающей трубки TD, недостаточно хладагента
03-1f не работает компрессор-из-за напряжения питания, перегрузки холодильного контура
03-08 неисправность четырёхходового клапана

Если не работает кондиционер Toshiba — это к нам!

Работы, выполняемые в ходе диагностики, соответствуют работам, производимым при сервисном обслуживании кондиционера. Отличие лишь в том, что в ходе диагностики проверяются и фиксируются все основные параметры работы оборудования, а при сервисном обслуживании устраняются выявленные отклонения от нормы.

Перечень работ при диагностике кондиционера

В ходе диагностики кондиционера, во-первых, проводится внешний осмотр на отсутствие механических повреждений. Осматриваются не только корпусные, но и гидравлические и электрические части оборудования. Кроме того, проверяется надежность креплений внешнего и внутреннего блоков. А также качество зажимов всех контактных соединений электрооборудования. Перед включением оборудования необходимо просмотреть состояние воздушных фильтров. Они должны быть не только чистыми, но и без повреждений. После осмотра, как правило, выполняется включение в режим «охлаждение». Для тестирования системы используйте пульт управления.

В ходе функциональной проверки оценивается индикация режимов кондиционера, а также работа выходных жалюзи с механическим приводом. Одним из косвенных показателей эффективности работы системы является контроль температуры сухого воздуха на входе и выходе из испарителя. С помощью манометров выполняется замер среднего давления всасывания/нагнетания (при свободном доступе к наружному блоку). Безусловно, обязательны к исполнению проверка герметичности соединения внутреннего и внешнего блоков. Кроме того, нужно убедиться в отсутствии утечек в дренажной системе кондиционера.

Если что-то пошло не так

О характере неисправности специалист может судить и по «поведению» кондиционера. Например, если кондиционер включается и сразу выключается, после чего высвечивается сообщение об ошибке – скорее всего, дело в сенсорах (неисправность датчиков температуры воздуха или испарителя).

Если кондиционер включается, работает 15-20 секунд, а затем выключается – скорее всего, неисправен мотор вентилятора внутреннего блока (скорость вращения ниже заданных оборотов в минуту).

Если кондиционер вообще не включается и при этом мигают (или не горят) все светодиоды – вероятнее всего, произошел выход из строя печатной платы управления.

Одновременное мигание всех индикаторных ламп кондиционера, как правило, означает лишь сбой программных установок платы управления. Скорее всего, это вызвано несоответствием ГОСТам параметров сети, например, из-за скачка напряжения в сети. Устранить эту неисправность несложно — достаточно лишь выполнить перепрограммирование основной платы управления. Так как информация о кодах предоставляется лишь уполномоченным сервисным центрам, в данном случае необходимо обратиться к нашим специалистам.

Прежде чем…

Если Ваш кондиционер не работает, прежде всего убедитесь, что кондиционер надежно подключен в розетку. Проверьте автомат защиты или плавкий предохранитель на питающей линии, при необходимости перезапустите автомат или замените предохранитель. Еще раз прочтите инструкцию пользователя и убедитесь, что все режимы установлены правильно.

Проделав это самостоятельно, Вы сэкономите свои деньги. Поскольку во многих случаях вызванный Вами инженер, проделав то, что Вы легко можете сделать сами, потребует оплату за ложный вызов.

Если эти действия не помогли, то свяжитесь с торговой организацией, продавшей Вам кондиционер. Или обратитесь в авторизованный сервисный центр производителя кондиционера. Безусловно, это наилучший, скорейший и надежный способ вернуть работоспособность Вашего кондиционера. Информацию о том, как с ними связаться, должна дать Вам торговая организация, продавшая кондиционер. Данная информация имеется не только в гарантийном талоне, но и на сайте производителя в соответствующем региональном разделе.

Тестовый режим кондиционера

Для облегчения диагностики в современных кондиционерах имеется так называемый тестовый режим работы. По сравнению с рабочим режимом, кондиционер включается в режим охлаждения и не реагирует на показания сенсоров и температуру воздуха. То есть, в тестовом режиме кондиционер будет функционировать столько, сколько это нужно сервисному инженеру для изучения работы блоков системы. После выключения тестового режима кондиционер вернется в обычный режим работы.

В кондиционерах Samsung также предусмотрен тестовый режим. Для ввода в режим проверки необходимо нажать на внутреннем блоке кнопку включения/выключения и удерживать ее в течение пяти секунд. При этом индикатор температуры выводит установленную опцию программных настроек с секундным интервалом, например, 0b0000-1730F8 : 0b00001730F80b (только для моделей с индикатором температуры).

В ходе тестирования работы кондиционера включается режим охлаждения со следующими ограничениями:
— Компрессор принудительно работает в режиме охлаждения без включения/выключения в соответствии с установленной внутренней температурой, без режима оттаивания;
— Лопасть, направляющая воздушный поток вверх/вниз — в режим поворота вверх-вниз;
— Внутренний вентилятор вращается на высокой скорости.

Если требуется ремонт кондиционера с заменой компрессора — это к нам!

Если вам не удалось исправить ошибки и устранить поломку кондиционера самостоятельно — Обратитесь к специалистам!
Наш опыт более 5 лет — Звоните, поможем!

C1 или CH1 — внутренний датчик температуры короткозамкнут или обрыв в цепи;

C2 или CH2 — внешний датчик температуры короткозамкнут или обрыв в цепи;

C4 или CH4 — температурный датчик конденсатора короткозамкнут или обрыв в цепи;

C5 или CH5 — соединение между внешним и внутренним блоками;

C6 или CH6 — превышен ток в  цепи инверторного модуля;

C7 или CH7 — превышен ток компрессора;

C8 или CH8 — не вращается вентилятор внутреннего блока;

C9 или CH9 — не вращается вентилятор внешнего блока;

CA — температура нагнетания выше 130 0С;

CC — ошибка EEPROM (внутренняя энергонезависимая память);

CD — ошибка в инверторном модуле;

CE

Po — система находится в энергосберегающем режиме, ошибки нет;

Lo — система находится в режиме тестирования,ошибки нет;

Набор кодов неисправностей зависит от модели кондиционера. Возможна и такая индикация кодов неисправностей в кондиционерах LG:

F01 —

Обрыв/замыкание room комнатного (воздушного)  датчика температуры внутреннего блока

F02 —

Обрыв/замыкание pipe датчика температуры внутреннего блока

F03 —

Отсутствие связи между пультом управления и основной платой управления более 2-х минут

F04 —

Обрыв/замыкание pipe датчика температуры внешнего блока

F05 —

Обрыв/замыкание room воздушного датчика температуры внешнего блока

Если система управления кондиционера обнаружила более одной ошибки, вначале индицируется неисправность, имеющая наименьший порядковый номер, а затем все остальные (по возрастанию порядкового номера ошибки). Коды ошибок кондиционеров LG приведены в табл. 1.

Таблица 1.
Код неис-правности Порядок мигания светодиода в случае возникновения неисправности Возможная причина неисправности Устранение неисправности
1 светодиод мигает 1 раз Неисправность одного из терморезисторов (разрыв или короткое замыкание) внутреннего (комнатного) блока аппарата — контроля температуры поступающего воздуха и трубки газового контура Проверяют исправность блока терморезисторов комнатного блока
2 светодиод мигает 2 раза Неисправность одного из терморезисторов (разрыв или короткое замыкание) наружного блока: датчика температуры поступающего воздуха или температуры трубки газового контура Проверяют исправность блока терморезисторов внешнего блока
3 светодиод мигает 3 раза Кондиционер работает одновременно и на обогрев и на охлаждение воздуха Повторно корректно устанавливают режимы работы кондиционера. Проверяют исправность систем управления нагревом и охлаждением воздуха
4 светодиод мигает 4 раза Выключена система защиты компрессора от перегрузки Проверяют исправность системы защиты компрессора от перегрузки
5 светодиод мигает 5 раз Ошибка обмена данными между комнатным и наружным блоками Проверяют кабельные линии, а также схемы обмена данными обоих блоков
6 светодиод мигает 6 раз Ток потребления одного или нескольких исполнительных устройств наружного блока кратковременно был выше нормы Проверяют исправность исполнительных устройства наружного блока и их элементы управления (ключевые силовые транзисторы)
7 светодиод мигает 7 раз Ток потребления всего наружного блока был выше нормы Проверяют давление хладагенте в системе, а затем исправность элементов наружного блока
8 светодиод мигает 8 раз Неисправность двигателя вентилятора Проверяют исправность двигателя, а также элементов схемы его управления
9 светодиод мигает 9 раз Неисправность 4 — ходового клапана Проверяют исправность клапана
10 светодиод мигает 10 раз Неисправен терморезистор контроля температуры корпуса компрессора (обрыв или короткое замыкание) Проверяют исправность терморезистора и при необходимости заменяют его

Следует отметить, что подобные ошибки могут возникнуть в случае, если параметры питающей сети (а также другие параметры — см. инструкцию по эксплуатации на конкретный тип аппарата) не удовлетворяют рекомендуемым значениям, а также в результате случайного сбоя системы управления кондиционером. Поэтому, прежде чем приступить к выявлению неисправности или обращаться в уполномоченный сервисный центр LG, необходимо обесточить аппарат, проверить питающую сеть, правильность выбора режимов работы аппарата, а затем снова включить его. В некоторых случаях ошибка может более не возникать.

Новые кондиционеры LG c  монтажем и гарантией 5 лет! Звоните!

Понравилась статья? Поделить с друзьями:

Не пропустите эти материалы по теме:

  • Яндекс еда ошибка привязки карты
  • Код ошибки код 8007371b
  • Код ошибки код 8000ffff
  • Код ошибки код 1951
  • Код ошибки клапана егр

  • 0 0 голоса
    Рейтинг статьи
    Подписаться
    Уведомить о
    guest

    0 комментариев
    Старые
    Новые Популярные
    Межтекстовые Отзывы
    Посмотреть все комментарии